INDUSTRIAL DUTY FIBERGLASS SHELTERS

For Highly Corrosive & Marine Locations 

Shelter Application 

Our Industrial Duty Fiberglass Shelters are intended for Chemical Processing or Waste water treatment areas where corrosive vapors such as Hydrogen Sulfide or Chlorine are present and offshore or coastal areas where salt-laden air or saltwater spray is prevalent.  Beyond corrosion resistance, the coating material utilized includes a glass fiber reinforced Class1 flame-retardant resin and UV resistance gel coating that is available in a variety of colors.

Construction Method 

Shelter Wall

Rib frame is fabricated of 80mm x 80mm x 3mm and 50mm x 50mm x 2mm metal tubes and then filled with Polyurethane foam insulation.   The inner and outer surfaces shall receive a spray coating of catalyst and resin based Gel and chop-sprayed glass fibers.  Material shall then be roller pressed to remove all trapped air and embed all fibers within the coating strata.  The Exterior shall then be lightly sanded, utilizing a combination of soft pad side grinders and orbital sanders to obtain a smooth finish and free of any visible blemishes or raised fibers. 

The surface shall receive a Flame-retardant Resin and Maine Grade UV Resistant Gel Coating Materials.

Shelter Roof 

Roof frame is made of 50mm x 50mm x 3mm Metal Tubes and then filled with Polyurethane foam insulation.  Top and bottom cover of the roof would be made of 6mm thick smooth GRP.  

For applications where climate is severe, slope of 4 inches per foot (4/12)  is provided suitable for heavy rain or snow.

The surface shall receive a Flame-retardant Resin and Maine Grade UV Resistant Gel Coating Materials.

Shelter Flooring 

Bottom steel frame would be made of 80mm x 80mm x 3mm profiles.  Over that a layer of 1.5mm thick Polyester Resin Lamination, 18mm thick BWP Grade Plywood and 4mm thick White Vinyl Tiles would be fixed respectively.  

Door

One piece made of Resin Transfer Molded in matched metal molds, smooth finished, seamless, monolithic, warp-free composite consisting of gel-coat, fiberglass reinforcement, polyester resin, insulating core and internal reinforcements with all mortises, openings, recesses and pockets molded in place as required.

Size:  30” x 70”
Weather strip:
  Neoprene sponge rubber bulb type gasket with flexible lock to retain permanent grip.
Type: 
Sweep door.
Latch: 
Single pointed keyed Stainless steel cylindrical latch.
Door Closer: 
Hydraulic.

Finish 

The surface shall receive a Flame-retardant Resin and Maine Grade UV Resistant Gel Coating Materials. 

Exterior Finish: Fiberglass Exterior Natural Suede.  Gel coat with low luster finish, smooth and free from fiber pattern, roughness or other irregularities.

Interior Finish:  FRB over insulation.  1/8” thick chemically bonded to Gel coat white in color.

Accessories

Mechanical 

1.
      Air conditioner 24000 BTU Hot and Cool. Single Phase:  1 ea.
2.      12 Port Entry Panel:  1 ea.
3.      18” width and up to 10’ Cable Rack Assembly:  1 ea.
4.       , Single Phase, 50

Electrical

1.
      Electrical Panel Board – 200 AMP Single Phase 50/60Hz:  1 ea.
2.      ¼” x 4” x 24” Ground Bars:  2 ea.
3.      Halo Ground System:  1 ea.
4.      4’ long Fluorescent light inside the shelter: 1 ea.
5.      13 Amp Switched Twin Socket mounted inside on walls:  6 ea.
6.       GFI Socket mounted out side:  1 ea.

Sensors & Alarms Alarm

1.      Smoke Detector:  1 ea.
2.      Temperature Difference Detector:  1 ea.
3.      Open Door Alarm:  1 ea.
4.      Power Failure Alarm:  1 ea.
5.      Motion Detector switched inside next to Door:  1 ea.

Packing  

All shelters would be wrapped in LDPF sheets to protect during transporting.  Store products on flat Surface and protect from construction traffic and damage. 

Installation   

Verify that the concrete pad is free of debris, level, true to plane and of correct dimensions to receive the structure.  Correct all deficiencies before proceeding.

UP ARMOR INSTALLATION & REFURBISH PROGRAM
Introduction
ALMC Armor Installation and Refurbishing programs are among the best in the SWA area.   ALMC is one of the lead contract supply and services providers for multinational military missions.
Our 100 plus expats are well trained, and experienced professionals in repairing and refurbishing military equipment.  ALMC experienced professionals can be at any service location in Kuwait, Afghanistan and Iraq as prime or in support of any company already at location.
ALMC delivers specialized services in the following areas:
::      Armor Installation (AOA)
::      Hummv 2 Door, 4-Door, Refurbish and Repair (M (939, M969)
::      Air Conditioning System (Installation & Repair)
::      Compressor System
::      Generators – (All Sizes)
::      Wiring Harness
::      Perform Inspection for front line completion
::      M1 Abrams
::      M2 Bradley
::      M 992 Ammo Carrier
::      M 109 Howitzer
::      M 113’s
::      2.5 Ton Trucks
::      5 Ton Trucks
 
   
           

Copyright © 2006-2007. Al Marwad. All rights reserved.
Powered By: hi5host